Critical · 10.0 Critical vulnerabilities CVE-2026-121932
Critical OS Command Injection in Linksys E5350 Router (CVE-2026-121932)
A critical, unauthenticated OS command injection vulnerability has been disclosed in the Linksys E5350 router. No vendor fix is currently available.
By PatchBriefing ·
Produced automatically from official sources with the help of AI. How we work →
AI summary
A security vulnerability has been publicly disclosed affecting the Linksys E5350 wireless router. The issue, tracked as CVE-2026-121932, allows an attacker to inject and execute operating system commands remotely without authentication. At the time of writing, no vendor patch is available and the vendor has not responded to disclosure attempts.
What happened
A vulnerability was identified in the Linksys E5350 router, version 1.0.00.037. The flaw resides in the 'system' function of the file /wizard/apply.cgi, where the ping_ip and traceroute_ip parameters are not properly sanitized before being used in a system-level command. By manipulating these arguments, an attacker can inject arbitrary operating system commands.
Technical cause
The vulnerability is classified under CWE-78 (OS Command Injection). The apply.cgi script's system function fails to validate or escape the ping_ip and traceroute_ip arguments, allowing user-supplied input to be passed directly into a system command. This can result in arbitrary command execution on the device with the privileges of the affected process.
Who is affected
Owners and administrators of Linksys E5350 routers running version 1.0.00.037 are affected. The attack can be initiated remotely and does not require authentication or user interaction, meaning any device exposing this interface to an attacker-reachable network is at risk.
Affected versions
The vulnerability has been confirmed in Linksys E5350 version 1.0.00.037. No information is available regarding whether other versions are affected.
Discovery and disclosure timeline
The vendor was contacted early about this disclosure but did not respond in any way. The vulnerability details and a public exploit are now available. There is no indication in the available facts that this vulnerability is being actively exploited in the wild.
Fixes and mitigation
No vendor fix is currently available for this vulnerability. Given the vendor's lack of response, administrators should consider mitigating exposure through other means, such as restricting network access to the device's management interface, until an official update is released.
Recommended action
Administrators of Linksys E5350 devices running version 1.0.00.037 should immediately restrict remote and untrusted network access to the device's web administration interface, particularly the /wizard/apply.cgi endpoint. Monitor for a vendor update and apply it as soon as one becomes available. Given the absence of a vendor response, consider replacing or isolating affected devices if remote management cannot be adequately restricted.
PatchBriefing score
10.0 / 10 · Critical
Official CVSS: 10.0
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P
EPSS 0.0429 (92 percentile)
Why this score
The PatchBriefing score equals the official CVSS score; when this article covers several vulnerabilities, the highest one. Signals such as known exploitation and EPSS are listed separately and do not change the score.
Affected versions
Reported fixes
No vendor fix is currently available for this vulnerability. Given the vendor's lack of response, administrators should consider mitigating exposure through other means, such as restricting network access to the device's management interface, until an official update is released.
How this was built
2 source records were collected, matched and used to prepare the report above.
-
NVD (NIST) database
-
CVE.org database
Revision history
- Published
- Generated