High · 7.8 Critical vulnerabilities CVE-2026-16305 VU#203719 CVE-2026-16306

INFINITT PACS System Manager: Local Privilege Escalation via Insecure Update Mechanism (CVE-2026-16305, CVE-2026-16306)

INFINITT PACS System Manager contains two local privilege escalation vulnerabilities in its update components, allowing a low-privileged local attacker to execute arbitrary commands with administrator rights. No fix is currently available.

By PatchBriefing · ·

Produced automatically from official sources with the help of AI. How we work →

AI summary

INFINITT Healthcare's PACS System Manager, used for managing medical imaging systems, has two newly disclosed vulnerabilities affecting its update components. Both allow a local attacker with limited privileges to execute arbitrary commands as administrator. No patched version has been published at the time of writing.

What happened

Two local privilege escalation vulnerabilities have been disclosed in INFINITT PACS System Manager, a product from INFINITT Healthcare. The issues affect the SmartUpdate.exe and SmartExecute.exe components used during application updates. A local, low-privileged attacker can modify a command manifest file to have it executed with administrator privileges.

Technical cause

The vulnerability is rooted in a world-writable file named execlist.txt, which is processed by SmartUpdate.exe and SmartExecute.exe during application updates. Because this manifest file can be modified by any local user regardless of privilege level, an attacker can insert arbitrary commands into it. When the update process runs with administrator privileges, it executes the attacker-controlled contents of the file, resulting in arbitrary command execution as administrator. This issue is classified under CWE-269 (Improper Privilege Management).

Why it matters

PACS (Picture Archiving and Communication System) software is used in healthcare environments to manage and store medical imaging data. A local privilege escalation vulnerability in such systems is significant because it can allow a low-privileged user or process to gain full administrative control over a machine that handles sensitive patient data, potentially enabling further compromise of the system or connected infrastructure.

Who is affected

Organizations running INFINITT PACS System Manager, as provided by INFINITT Healthcare, are affected. No specific affected version numbers were provided in the available advisory information.

Affected versions

The available advisory information does not specify which versions of System Manager are affected. We cannot confirm a version range at this time.

Fixes and mitigation

No fix is currently available for these vulnerabilities, according to the available advisory information. Organizations running the affected product should monitor for updates from INFINITT Healthcare and consider restricting local access to systems running System Manager until a fix is released.

Recommended action

Until a vendor fix becomes available, limit local user access to systems running INFINITT PACS System Manager, and restrict write permissions on update-related directories and files where possible. Monitor official INFINITT Healthcare channels for a security update addressing CVE-2026-16305 and CVE-2026-16306.

PatchBriefing score

7.8 / 10 · High

Official CVSS: 7.8

CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

EPSS 0.0098 (61 percentile)

Why this score

The PatchBriefing score equals the official CVSS score; when this article covers several vulnerabilities, the highest one. Signals such as known exploitation and EPSS are listed separately and do not change the score.

Affected versions

Reported fixes

No fix is currently available for these vulnerabilities, according to the available advisory information. Organizations running the affected product should monitor for updates from INFINITT Healthcare and consider restricting local access to systems running System Manager until a fix is released.

How this was built

5 source records were collected, matched and used to prepare the report above.

  • CERT/CC Vulnerability Notes cert
  • NVD (NIST) database
  • NVD (NIST) database
  • CVE.org database
  • CVE.org database
Unified report
INFINITT PACS System Manager: Local Privilege Escalation via Insecure Update Mechanism (CVE-2026-16305, CVE-2026-16306)
1 article · 5 sources cited
Revision history
  1. Published
  2. Generated
  3. Published
  4. Early Warning
The Morning Brief

Relevant changes for the stacks you follow.

Choose your stacks, topics and optional WordPress plugins. At 07:00 CET, matching advisories and releases from the reporting period are grouped into one email.

✓ Choose stacks and topics✓ Change preferences anytime✓ One grouped email