Critical · 10.0 Critical vulnerabilities CVE-2026-120387
Critical Authentication Bypass in CIRCUTOR PowerStudio SCADA Wave via JWT Signature Flaw
CIRCUTOR PowerStudio SCADA Wave desktop contains a critical flaw (CVE-2026-120387) where the JWT validation component accepts unsigned tokens, letting unauthenticated remote attackers impersonate any user. No fix is currently available.
By PatchBriefing ·
Produced automatically from official sources with the help of AI. How we work →
AI summary
A critical authentication bypass vulnerability has been identified in CIRCUTOR PowerStudio SCADA Wave, a desktop SCADA application. Tracked as CVE-2026-120387, the issue stems from improper verification of JSON Web Token (JWT) signatures, allowing an attacker without any credentials to impersonate legitimate users and gain access to protected functionality. At the time of writing, no fix is available from the vendor.
What happened
A vulnerability has been disclosed in CIRCUTOR PowerStudio SCADA Wave, affecting the shared component responsible for validating JSON Web Tokens (JWTs). The component fails to verify the cryptographic signature of a submitted token, which allows an attacker to craft and submit an unsigned JWT and have it accepted as valid.
Technical cause
The root cause is classified as improper verification of a cryptographic signature (CWE-347). The JWT validation logic accepts tokens where the algorithm field is set to 'none', meaning no signature is required at all. By submitting such a token, an unauthenticated remote attacker can impersonate another user and inherit that user's privileges within the application, without needing to know any credentials or secret signing keys.
Why it matters
Because the flaw allows full authentication bypass over the network without any user interaction, an attacker can gain unauthorized access to protected SCADA functionality. Depending on the privileges of the impersonated user, this could allow access to monitoring data or administrative functions within the PowerStudio SCADA Wave environment. SCADA systems are often used to monitor and manage industrial or electrical infrastructure, which raises the potential impact of unauthorized access.
Who is affected
Organizations running the CIRCUTOR PowerStudio SCADA Wave desktop application are affected. The fact package does not specify particular version numbers, so we cannot confirm whether the issue is limited to specific releases or applies to all deployments of the product.
Affected versions
No specific version numbers are provided in the available advisory data. Administrators should treat all currently deployed installations of PowerStudio SCADA Wave desktop as potentially affected until the vendor publishes version-specific guidance.
Fixes and mitigation
No fix is currently available for this vulnerability according to the available advisory data. Until a vendor update is released, organizations should consider network-level mitigations, such as restricting access to the PowerStudio SCADA Wave application to trusted, segmented networks, and monitoring for unusual authentication activity.
Recommended action
Restrict network exposure of PowerStudio SCADA Wave to trusted hosts and segmented environments as an immediate precaution. Monitor vendor channels for an official patch addressing CVE-2026-120387, and apply it as soon as it becomes available. In the meantime, review access logs for signs of unexpected privilege use that could indicate exploitation of this flaw.
PatchBriefing score
10.0 / 10 · Critical
Official CVSS: 10.0
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H
EPSS 0.0061 (43 percentile)
Why this score
The PatchBriefing score equals the official CVSS score; when this article covers several vulnerabilities, the highest one. Signals such as known exploitation and EPSS are listed separately and do not change the score.
Affected versions
Reported fixes
No fix is currently available for this vulnerability according to the available advisory data. Until a vendor update is released, organizations should consider network-level mitigations, such as restricting access to the PowerStudio SCADA Wave application to trusted, segmented networks, and monitoring for unusual authentication activity.
How this was built
2 source records were collected, matched and used to prepare the report above.
-
CVE.org database
-
NVD (NIST) database
Revision history
- Published
- Generated